| APPA-A7 APPA-A8 APPA-A9 APPA-A12 APPA-A16 | ||
| Specifications | ||
| Voltage AC | ||
| APPA A7, A7D | ||
| Range: 600V | ||
| Basic Accuracy: +/-(1.5%+3d) | ||
| APPA A5, A8 | ||
| Range: 200.0V (A5), 750V | ||
| Basic Accuracy: +/-(1.5%+3d) | ||
| APPA A7A, A9, A6 | ||
| Range: 1.0~750.0V | ||
| Basic Accuracy: +/-(1.5%+3d) | ||
| APPA A7, A7D | ||
| Overload Protection: 600V DC or AC rms | ||
| APPA A5, A7A, A8, A9, A6 | ||
| Overload Protection: 750V rms | ||
| Conversion Type: Average sensing RMS indicating | ||
| Voltage DC | ||
| APPA A7, A7D | ||
| Range: 600V | ||
| Basic Accuracy: +/-(1.0%+2d) | ||
| APPA A5, A8 | ||
| Range: 200.0V (A5), 1000V | ||
| Basic Accuracy: +/-(1.0%+3d) | ||
| APPA A7A, A9, A6 | ||
| Range: 1.5~999.9V, -0.2V~-999.9V | ||
| Basic Accuracy: +/-(1.0%+2d) | ||
| APPA A7, A7D | ||
| Overload Protection: 600V DC or AC rms | ||
| APPA A5, A7A, A8, A9, A6 | ||
| Overload Protection: 1000V DC or AC peak | ||
| Current AC | APPA A7, A7D, A5, A8 | |
| Range: 200.0A | ||
| Basic Accuracy: +/-(3.0%+3d) 45Hz~66Hz | ||
| APPA A7A | ||
| Range: 0.3A~200.0A | ||
| Basic Accuracy: +/-(1.8%+3d) 50Hz~60Hz | ||
| APPA A9 | ||
| Range: 0.3A~400.0A | ||
| Basic Accuracy: +/-(1.8%+3d) 50Hz~60Hz | ||
| APPA A6 | ||
| Range: 0.3A~600.0A | ||
| Basic Accuracy: +/-(2.0%+1A) 50Hz~60Hz | ||
| Conversion Type: Average sensing RMS indicating | ||
| Resistance | APPA A7, A7D, A5, A8 | |
| Range: 2000Ω | ||
| Basic Accuracy: +/-(1.0%+2d) | ||
| APPA A7A, A9, A6 | ||
| Range: 2000Ω | ||
| Basic Accuracy: +/-(2.0%+2d) | ||
| Overload Protection: 600V rms | ||
| Continuity Beeper | ||
| APPA A7, A7D, A8 | ||
| Threshold: <25Ω | ||
| APPA A5 | ||
| Threshold: <100Ω | ||
| APPA A7A, A9, A6 | ||
| Threshold: <200Ω | ||
| Indicator: 2kHz tone buzzer | ||
| Diode Test | ||
| APPA A7, A7D, A5, A8, A7A, A9, A6 | ||
| Open circuit Voltage: 3V | ||
| Gerneral Specifications | ||
| Sampling Rate | ||
| APPA A7, A7D, A5, A8 | ||
| 2.5 times/sec | ||
| APPA A7A, A9, A6 | ||
| 5 times/sec | ||
| Overload Indication | APPA A7, A7D, A5, A8 | |
| OL is displayed for "A" and "Ω" functions. Show the real value for "V" | ||
| function | ||
| APPA A7A, A9, A6 | ||
| "OL" or "-OL" | ||
| Low Battery Indication | ||
| Auto Power Off | Approx. 30 minutes | |
| Operating Temperature | ||
| -20ºC~ 50ºC, <80% RH | ||
| Sotreage Temperature | ||
| -20ºC~ 60ºC | ||
| Temperature Coefficient | ||
| 0.15(Spec. Acc)/ºC, <18ºC or >28ºC | ||
| Safety | APPA A7, A7D | |
| CAT. III 600V | ||
| APPA A8, A9, A6 | ||
| CAT. III 600V/ CAT. II 1000V | ||
| APPA A5, A7A | ||
| CAT. IV 600V/ CAT.III 1000V | ||
| IEC61010 and designed to meet UL61010 specifications | ||
| Maximum Conductor Size | APPA A7 | |
| 12mm dia. | ||
| APPA A7D, A7A, A5 | ||
| 16mm dia. | ||
| APPA A8 | ||
| 23mm dia. | ||
| APPA A9 | ||
| 27mm dia. | ||
| APPA A6 | ||
| 32mm ida. | ||
| Maximum Jaw Opening | ||
| APPA A7 | ||
| 12mm dia. | ||
| APPA A7D, A7A, A5 | ||
| 16mm dia. | ||
| APPA A8 | ||
| 28mm dia. | ||
| APPA A9 | ||
| 35mm dia. | ||
| APPA A6 | ||
| 38mm ida. | ||
| Power Requirement | ||
| Single 9V battery (NEDA 1604 or IEC 6F22) | ||
| Battery Life | ||
| APPA A7, A7D, A7A, A5, A9, A6 | ||
| 250 hours (Alkaline battery) | ||
| APPA A8 | ||
| 300 hours (Alkaline battery) | ||
| Size | ||
| APPA A7 | ||
| 65mm (W) x 185mm (L) x 40mm (H) | ||
| APPA A7D, A7A | ||
| 84mm (W) x 175mm (L) x 31mm (H) | ||
| APPA A5, A8, A9 | ||
| 66mm (W) x 198mm (L) x 46mm (H) | ||
| APPA A6 | ||
| 83mm (W) x 200mm (L) x 48mm (H) | ||
| Weight | ||
| APPA A7, A7D, A5, A7A | ||
| 280 grams | ||
| APPA A8, A9 | ||
| 260 grams | ||
| APPA A6 | ||
| 375 grams | ||
| Included with Instrument | ||
| APPA A7, A7D, A5, A7A, A8, A9 | ||
| Test Leads, ZnC battery (installed) and Manual | ||
| APPA A6 | ||
| Also included with Deluxe carrying Case | ||