Specifications  
 Voltage AC   APPA 33/33R, 35N/35R, 39AC/39AR, 39MR
  Range:                                       400.0V~600V
  Basic Accuracy:                      +/-(1.2%+5d) at 40Hz(39MR at 50Hz) ~500Hz
  APPA 36II/36RII, 30/30R
  Range:                                       400.0mV~600V
  Basic Accuracy:                      +/-(1.5%+5d) at 40Hz~500Hz
  APPA 33II/33RII
  Range:                                       600V
  Basic Accuracy:                      +/-(1.2%+3d) at 40Hz~500Hz
     
  APPA 33/33R, 35N/35R, 33II/33RII, 39AC/39AR, 36II/36RII, 30/30R,39MR
  Overload Protection:              600V rms
  Input Impedance:                    10MΩ//100pF
 
  APPA 33, 35N, 33II, 39AC, 36II, 30
  Conversion Type:                    Average sensing RMS indicating
  APPA 33R, 35R, 33RII, 39AR, 36RII, 30R, 39R, 39MR  
  Conversion Type:                    True RMS
 
 Voltage DC  
  APPA 39AC/39AR
  Range:                                       400.0V~1000V 
  Basic Accuracy:                      +/-(0.7%+5d)
  APPA 36II/36RII
  Range:                                        400.0mV~600V
  Basic Accuracy:                      +/-(0.7%+2d)
  APPA 30/30R
  Range:                                        400.0mV~600V
  Basic Accuracy:                      +/-(0.5%+2d)
  APPA 39MR
  Range:                                        400.0V,1000V
  Basic Accuracy:                      +/-(0.7%+2d)
  
  APPA 36II/36RII
  Overload Protection:               600V rms
  APPA 39AC/39AR, 39MR
  Overload Protection:               1000V DC or AC Peak
 
 Current AC  
  APPA 31
  Range:                                        400.0A 
  Resolution:                                1mV/A
  Basic Accuracy:                       +/-(1.9%+0.5A) at 50Hz~60Hz                         
  APPA 32
  Range:                                        100.0A, 600A 
  Resolution:                                10mV/A, 1mV/A
  Basic Accuracy:                       +/-(2.0%+2A) at 45Hz~400Hz
  APPA 30T
  Range:                                        40.00A, 300.0A
  Resolution:                                10mV/A, 1mV/A
  Basic Accuracy:                       +/-(1.0%+0.1A) at 40Hz~400Hz
  APPA 39T
  Range:                                        100.0A, 1000A
  Resolution:                                10mV/A, 1mV/A
  Basic Accuracy:                       +/-(1.9%+2A) at 40Hz~400Hz 
 
  APPA 33/33R, 36II/36RII
  Range:                                        400.0A,600A
  Basic Accuracy:                       +/-(1.9%+5d) at 50Hz~60Hz                         
  APPA 39AC/39AR, 39, 39R, 39MR
  Range:                                        400.0A, 1000A (1200A for 39AC)
  Basic Accuracy:                       +/-(1.9%+5d) (39AC/39AR) at 50Hz~60Hz
                                                        +/-(1.9%+7d) (39/39R) at 40Hz~400Hz
                                                        +/-(1.5%+5d) (39MR) at 40Hz~400Hz
  APPA 35N/35R
  Range:                                        400.0A
  Basic Accuracy:                       +/-(1.9%+5d) at 50Hz~60Hz
  APPA 33II/33RII
  Range:                                        200.0A, 600A
  Basic Accuracy:                       +/-(1.5%+5d) at 50Hz~60Hz
  APPA 30/30R
  Range:                                        40.00A, 300.0A
  Basic Accuracy:                       +/-(1.0%+3d) at 50Hz~60Hz
 
 
  APPA 33, 35N, 33II, 39AC, 36II, 30
  Conversion Type:                    Average sensing RMS indicating
  APPA 33R, 35R, 33RII, 39AR, 36RII, 30R, 39R, 39MR  
  Conversion Type:                    True RMS
 
 Current DC        
  APPA 32
  Range:                                        100.0A, 600A 
  Resolution:                                10mV/A, 1mV/A
  Basic Accuracy:                       +/-(2.0%+2A) 
  APPA 30T
  Range:                                        40.00A, 300.0A
  Resolution:                                10mV/A, 1mV/A
  Basic Accuracy:                       +/-(1.0%+0.1A) 
  APPA 39T
  Range:                                        100.0A, 1000A
  Resolution:                                10mV/A, 1mV/A
  Basic Accuracy:                       +/-(1.9%+7A)  
 
  APPA 36II/36RII 
  Range:                                         400.0A,600A
  Basic Accuracy:                       +/-(1.5%+7d)
  APPA 30/30R
  Range:                                         40.00A,300.0A
  Basic Accuracy:                       +/-(1.0%+2d)
  APPA 39/39R
  Range:                                         400.0A,1000A
  Basic Accuracy:                       +/-(1.9%+7d)
  APPA A18plus
  Range:                                         400.0A, 1000A
  Basic Accuracy:                       +/-(1.0%+3d)
 
 Resistance  
  APPA 33/33R, 35N/35R, 39AC/39AR, 39MR
  Range:                                         4.000KΩ,40.00KΩ
  Basic Accuracy:                       +/-(2.0%+9d) (33/33R)
                                                        +/-(1.9%+8d) (35N/35R)
                                                        +/-(2.0%+9d) (39AC/39AR)
                                                        +/-(1.0%+2d) (39MR)
  APPA 33II/33RII
  Range:                                         2000Ω
  Basic Accuracy:                       +/-(1.5%+2d)
  APPA 36II/36RII, 30/30R
  Range:                                         400.0Ω~40MΩ
  Basic Accuracy:                       +/-(0.9%+3d)
 
  Overload Protection:                 600V rms
 
 Continuity  
  APPA 33/33R
  <200Ω, 2KHz tone buzzer
  APPA 35N/35R, 39AC/39AR, 39MR
  <100Ω, 2KHz tone buzzer
  APPA 33II/33RII, 36II/36RII, 30/30R
  <50Ω, 2KHz tone buzzer
 
 Frequency Counter  
  APPA 39/39R
  Range:                                       20Hz~1kHz 
  Basic Accuracy:                      +/-(0.5%+3d)
 
 Output Voltage  
  APPA 31
  AC 1mV/ A
  APPA 32
  AC/DC, 10mV/A in 100A, 1mV/A in 600A
  APPA 30T
  AC/DC, 10mV/A in 40A, 1mV/A in 300A
  APPA 39T
  AC/DC, 10mV/A in 100A, 1mV/A in 1000A
 
 Position Error  
  +/-1%rdg
 
 Load Impedance  
  APPA 30T, 39T
  AC/DC 100kΩ min
 
 Type of Sensing  
  APPA 31, 33/33R, 35N/35R, 33II/33RII, 39AC/39AR
  Current transformer sensing
  APPA 32, 30T, 39T, 36II/36RII, 30/30R, 39/39R, 39MR
  Hall effect sensing for AC and DC
 
 General Specifications
 Display  
  APPA 33/33R, 35N/35R, 39AC/39AR, 36II/36RII, 30/30R, 39/39R, 39MR
  4000 count
  APPA 33II/33RII
  2000 count
 
 Sampling Rate  
  APPA 33/33R, 35N/35R, 39AC/39AR
  4times/sec
  APPA 33II/33RII
  2.5times/sec
  APPA 36II/36RII, 30/30R, 39/39R, 39MR
  2times/sec 
 
 Overload Indication  
  "OL" or "-OL"
 
 Low Battery Indication  
 Auto Power Off  
  Approx. 30 minutes (39MR at 10 minutes)
 
 Operating Temperature  
  -20ºC~ 50 167C, <80% RH 
 
 Storage Temperature  
  -20ºC~ 60ºC
 
 Temperature Coefficient  
  0.15(Spec. Acc)/ºC, <18ºC or >28ºC
 
 Shock Proof  
  4 feet drops
 
 Safety  
  IEC 61010 and designed to meet UL61010 specifications
 
  APPA 31, 32, 33/33R, 35N/35R, 30/30R
  CAT. II 600V
  APPA 30T, 36II/36RII 
  CAT. III 600V
  APPA 33II/33RII, 39AC/39AR, 39/39R, 39MR
  CAT. III 600V/CAT. II 1000V
  APPA 39T
  CAT. III 1000V
 
 Maximum Conductor Size  
  APPA 30T, 30/30R
  22mm dia. (350MCM)
  APPA 31, 35N/35R 
  29mm dia. (600MCM)
  APPA 32, 33II/33RII
  34mm dia. (750MCM)
  APPA 36II/36RII
  35mm dia. (750MCM)
  APPA 33/33R
  40mm dia. (750MCM)
  APPA 39T, 39AC/39AR, 39/39R, 39MR
  51mm dia. (2000MCM)
 
 Maximum Jaw Opening  
  APPA 30T, 30/30R
  25mm  
  APPA 31, 35N/35R 
  30mm  
  APPA 32, 33II/33RII
  38mm 
  APPA 36II/36RII
  45mm 
  APPA 33/33R
  42mm
  APPA 39T, 39AC/39AR, 39/39R, 39MR
  53mm 
 
 Maximum Busbar Size  
  APPA 32
  20mm x 40mm 
  APPA 36II/36RII
  40mm x 15mm
  APPA 39T, 39/39R, 39MR
  24mm x 60mm
 Power Requirement  
  APPA 32, 30T, 39T, 33/33R, 35N/35R, 33II/33RII, 39AC/39AR, 36II/36RII
  39/39R, 39MR
  Single 9V battery (NEDA 1604 or IEC 6F22)
  APPA 30/30R
  IEC LR03, AM4 or AAA size 1.5V x 2
 
 Battery Life  
  APPA 30T, 39T
  66 hours (Alkaline)
  APPA 33/33R, 35N/35R , 33II/33RII, 39AC/39AR
  200 hours (Alkaline)
  APPA 32
  45 hours (Alkaline)
  APPA 36II/36RII
  150 hours (Alkaline)
  APPA 30/30R
  50 hours (Alkaline)
  APPA 39/39R, 39MR
  40 hours (Alkaline)
 
 Size  
  APPA 30T
  60mm (W) x 203mm (L) x 27mm (H) w/o cable
  APPA 30/30R
  66mm (W) x 192mm (L) x 32mm (H)
  APPA 31 
  77mm (W) x 148mm (L) x 36mm (H) w/o cable
  APPA 35N/35R
  77mm (W) x 194mm (L) x 36mm (H)
  APPA 32 
  60mm (W) x 203mm (L) x 27mm (H) w/o cable
  APPA 33II/33RII
  76mm (W) x 200mm (L) x 41mm (H)
  APPA 36II/36RII
  82mm (W) x 208mm (L) x 41mm (H)
  APPA 33/33R
  88mm (W) x 215mm (L) x 36mm (H)
  APPA 39AC/39AR, 39/39R, 39MR
  105mm (W) x 268mm (L) x 41mm (H)
  APPA 39T
  65.5mm (W) x 185mm (L) x 40mm (H) w/o cable
 
 Weight  
  APPA 31, 35N/35R
  250 grams  
  APPA 32
  380 grams
  APPA 30T, 33/33R  
  250 grams
  APPA 39T, 39AC/39AR, 39/39R, 39MR
  420 grams
  APPA 33II/33RII, 36II/36RII
  360 grams
  APPA 30/30R
  205 grams
  
 Included with Instrument  
   APPA 33/33R, 35N/35R, 33II/33RII, 39AC/39AR, 36II/36RII, 30/30R
   39/39R, 39MR
   Safety Test leads, ZnC battery(Installed)(39MR installed alkaline
   battery), User’s Manual and Carrying Case 
   APPA 31, 32, 30T, 39T
   Coiled cable output plugs, ZnC battery(Installed)(31has no battery)
   User’s Manual and Carrying Case