APPA-72 / 73 / 79
Especificaciones básicas
  Voltage DC   APPA 71/72/73
  Range:                                 600.0mV~1000V
  Accuracy:                             +/-(0.5%+2d)
  APPA 75/77/79
  Range:                                 400.0mV~1000V
  Accuracy:                             +/-(0.5%+2d)
  Overload Protection:         1000Vrms
  Voltage AC   APPA 71/72/73
  Range:                                 600.0mV~750V
  Accuracy:                             +/-(0.9%+5d)
  APPA 75/77/79
  Range:                                 400.0mV~750V
  Accuracy:                             +/-(1.2%+5d)
  APPA 71/75
  Conversion Type:              Average sensing RMS indicating
  APPA 72/73/77/79
  Conversion Type:              True RMS 
   Frequency Resonse:       50Hz~500Hz
   Overload Protection:       1000V rms
  Current DC   APPA 71
  Range:                                 600.0uA, 6000uA
  Accuracy:                             +/-(1.0%+2d)
  APPA 72/73
  Range:                                 600.0uA, 6000uA, 6.000A, 10.00A
  Accuracy:                             +/-(1.0%+2d)
  APPA 75
  Range:                                 400.0uA, 4000uA
  Accuracy:                             +/-(1.0%+2d)
  APPA 77/79
  Range:                                 400.0uA, 4000uA, 10.00A
  Accuracy:                             +/-(1.0%+2d)
  Input Proection:                  600V rms for uA input
                                                10A/500V fast blow fuse for A input  
  Current AC   APPA 72/73
  Range:                                 6.000A, 10.00A
  Accuracy:                            +/-(1.5%+5d)
  APPA 77/79
  Range:                                 10.00A
  Accuracy:                            +/-(1.5%+5d)
  Input Protection:               10A/500V fast blow fuse for A input 
  Resistance   APPA 71/72/73
  Range:                                 600.0Ω~60.00MΩ
  Accuracy:                             +/-(0.7%+2d)
  APPA 75/77/79
  Range:                                 400.0Ω~40.00MΩ
  Accuracy:                             +/-(0.7%+2d)
  Overload Protection:         600V rms
    APPA 71/72/73
  <150Ω, 2kHz tone buzzer
  APPA 75/77/79
  <350Ω, 2kHz tone buzzer
  Diode Test   Open Circut Voltage:        3V
  Frequency Counter   APPA 71/72/73
  Range:                                 6000Hz~60.00MHz
  Accuracy:                            +/-(0.01%+1d) 
  APPA 75/77/79
  Range:                                4KHz~40.00MHz
  Accuracy:                            +/-(0.01%+1d)
 Capacitance   Overload Protection:         600V rms
  APPA 71/72/73
  Range:                                  6.000nF~6.000mF
  Accuracy:                             +/-(1.9%+8d)
  APPA 75/77/79
  Range:                                  4.000nF~4.000mF
  Accuracy:                              +/-(1.9%+8d)
  Overload Protection:          600V rms
 General Specifications
 Sampling Rate   1.5 tims/sec
 Overload Indication   "OL" or "-OL"
 Low Battery Indication  
 Auto Power Off   APPA 71/72/73
  approx. 10 minutes
  APPA 75/77/79
  approx. 30 minutes
 Operating Temperature   0?~50?, <80%RH
 Storage Temperature   -20?~60?
 Temperature Coefficient   0.15(Spec. Acc.)/?, <18? or >28?
 Safety   IEC61010 and designed to meet UL3111 specificatons
 Power Requirement   APPA 72/73/77/79
  Single 9V battery (NEDA 1604 or IEC 6F22)
  APPA 71/75
  IEC LR03, AM4 or AAA size 1.5V x 2  
 Battery Life   300 hours
 Size   76mm(W) x 158mm(L) x 38mm(H), without holster
  82mm(W) x 164mm(L) x 44mm(H), with holster
 Weight   400 grams (with holster)
 Included with Instrument   Test Leads, Protective holster, ZnC battery(installed) and manual