APR-5000/ APR-5000XLS
APR-5000 Array Package Rework System
Design and functionality come together in the compact and powerful APR-5000 Array Package Rework System. This system provides closed-loop control, optimized vision and precise component placement on a compact platform of 19" x 30" (483mm x 762mm).

Capable of handling boards up to 9" x 15" (229mm x 381mm), with a placement accuracy to 0.001" (0.025mm) and interconnection pitches as low as 0.012" (0.3mm), the APR-5000 is ideal for reworking smaller assemblies such as cell phones and laptop computers.

In addition, the APR-5000 Array Package Rework System uses standard line voltages and self contained pumps rather than special wiring and shop air. This allows the system to be set up and moved to any bench, without having to be fitted/plumbed in by an engineer. The system also offers N2 as a standard software option, however, a nitrogen supply is required.
The system also incorporates OK International's exclusive integral vision system that makes viewing, aligning and accurately placing a component easy by allowing operators to simultaneously view the topside of the PCB and a superimposed image of the underside of the component. Then, with micrometer adjustment, images can be accurately aligned in the X, Y & Theta axes prior to placement. In addition, integrating the vision system with the machine's software eliminates the need for multiple monitors.
SYSTEMS
Part No. Description
APR-5000 100-240 VAC Array Package Rework System
APR-5000-XLS 200/240 VAC Array Package Rework System with Split Vision
APR-5000-XL 200/240 VAC Array Package Rework System
Systems will be configured with desktop PC and monitor.
Final pricing will depend on configuration and language version.
TECHNICAL SPECIFICATIONS
Input Voltage APR-5000 APR-5000-XLS/XL
100-240 VAC, 200-240 VAC,
50/60 Hz 50/60 Hz
Single Phase 20 Amp Single Phase
Power Consumption
  System Total 2200 W 3500 W
  Pre-Heater 1400 W 2800 W
Inner Zone   1400 W
Outer Zone   2800 W
  Reflow Heater 550 W 550 W
Temperature Control Type Closed-Loop Control Closed-Loop Control
(RTD Sensors) (RTD Sensors)
Maximum Source Temperature
  Reflow Head 400 °C (842 °F) 400 °C (842 °F)
  Pre-Heater 350 °C (662 °F) 350 °C (662 °F)
Airflow
  Control Pre-Set to 8,16 & 24 l/min Pre-Set to 8,16 & 24 l/min
  Supply Self-Contained Pump Self-Contained Pump
  Optional Standard Feature Standard Feature
  Nitrogen
  Input
Component Handling
  Maximum Size 1.4" x 1.4" (35mm x 35mm) 2.2" x 2.2"*
(56mm x 56mm)
1.4" x 1.4"**
(35mm x 35mm)
  Minimum Size 0.020" x 0.010" 0.020" x 0.010"
(0.51mm x 0.25mm) (0.5 1 mm x 0.25mm)
  Maximum Weight 55g (1.94oz) 55g (1.94oz)
PCB Handling Capability
  Maximum Size 15" x 9" 24.5" x 24.5"
(381mm x 229mm) (622mm x 622mm)
  Rework Area 9" x 12" 22.5" x 24.5"
(229mm x 305mm) (572mm x 622mm)
  Maximum Thickness 0.25 "(6mm) 0.25 "(6mm)
Vision
  Maximum Field of View 1.4" x 1.4" 2.2" x 2.2"
(35mm x 35mm) (56mm x 56mm)
  Split Field (APR-5000-XLS)   Corner crossover on large component
System Dimensions
  W x D x H 19" x 30" x 30" 36" x 36" x 33"
(483mm x 762mm x 762mm) (914mm x 914mm x 838mm)
  Weight 130lbs (59Kg) 220lbs (100Kg)
System Warranty 1 Year (Excluding Consumables) 1 Year (Excluding Consumables)
Agency Approvals CE CE
cETLus cTUVus
  GS
(*APR-5000-XLS,**APR-5000-XL)