| Hioki-3285 |
| Analysis for DC to
distorted waves |
| 2000 Arms, clamp aperture: 55 mm(2.17 in) dia. |
|
| Inrush current
crest value |
| RMS value of
full-wave rectified waveforms |
| Waveform and
harmonic analysis |
|
|
| Especificaciones
básicas |
|
| AC Current range |
AC (RMS or Peak value)200.0 or
2000 A AC, 2 ranges (±1.3 % rdg. ±3 dgt. at 50 or 60Hz), AC+DC (RMS or Peak
value)200.0 or 2000 A AC, 2 ranges (±1.3 % rdg. ±13 dgt. at 50 or 60Hz),
Effective value rectifier |
| DC
Current range |
DC (Average or Peak value)200.0
or 2000 A DC, 2 ranges (±1.3 % rdg. ±3 dgt.) |
| AC
Voltage range |
AC (RMS or Peak value)30.00 to
600 V AC, 3 ranges (±1.0 % rdg. ±3 dgt. at 50 or 60Hz), AC+DC (RMS or Peak
value)30.00 to 600 V AC, 3 ranges (±1.0 % rdg. ±7 dgt. at 50 or 60Hz),
Effective value rectifier |
| DC
Voltage range |
DC (Average or Peak value)30.00
to 600 VDC, 3 ranges (±1.0 % rdg. ±3 dgt.) |
| Other
functions |
Frequency: 10 to 1000 Hz; Mode:
Max./Min./AVE./RMS Record mode/Auto-off; Resistance (3285-20 only): 1 k or 10
k-ohm range |
| Analog
output (3285 only) |
DC, or AC 1 V /f.s., Level
output: with REC mode, Waveform output: with MON mode |
| Frequency
characteristics (at AC current / voltage) |
DC, 10 to 1 kHz |
| Display
section |
Current / 2500 dgt. Voltage /
3750 dgt. Bar graph / 35 seg. |
| Sampling
rate |
2 or 4 times/sec (Slow: 1 time/3
sec) |
| Crest
factor (RMS) |
2.5 (1.7 at 600 V range), 1.42
(2000 A range) |
| Max.
circuit voltage |
600 V AC rms (insulated wire) |
| Power
supply |
6F22(006P)
× 1 (Continuous use - 3285: 25 hours; 3285-20: 16 hours), or AC adapter (3285
only) |
| Core
jaw dia. |
Ř 55 mm(2.17 in) |
| Dimensions,
mass |
62 mm(2.44 in)W × 260 mm(10.24
in)H × 39 mm(1.54 in)D, 540 g (19.0 oz) |
| Accessories |
TEST LEAD 9207-10 (1), CARRYING
CASE 9345 (1), Hand strap (1) |
|
|