| HIOKI 3287 |
| Compact & easy, one-touch maintenance on all types of
AC/DC equipment |
|
|
| True RMS |
| Puede medir una pequeña corriente de uso con 10 A Rango de
tensión, resistencia, continuidad función de comprobación |
|
|
| DC Current |
10.00/ 100.0 A,
Basic accuracy: ±1.5 % rdg. ±5 dgt. |
| AC
Current |
10.00/ 100.0 A, (10 Hz to 1 kHz,
True RMS), Basic accuracy: ±1.5 % rdg. ±5 dgt. |
| DC
Voltage |
419.9 mV to 600 V, 5 ranges,
Basic accuracy: ±1.3 % rdg. ±4 dgt. |
| AC
Voltage |
4.199 V to 600 V, 4 ranges,
Basic accuracy: ±2.3 % rdg. ±8 dgt. (30 to 500 Hz, True RMS) |
| Resistance |
419.9 Ω to 41.99 MΩ, 6
ranges, Basic accuracy: ±2 % rdg. ±4 dgt. |
| Crest
factor |
2.5 and under (150 A, 1000 V
max.) |
| Other
function |
Continuity: (50 Ω ±40
Ω) or less buzzer sounds, Data hold, Auto power save, Auto zero (DC A) |
| Display |
LCD, max. 4199 dgt., Display
refresh rate: 2.5 times/s |
| Power
supply |
Coin type lithium battery
(CR2032) ×1, Continuous use 25 hours |
| Core jaw
dia. |
φ 35 mm (1.38 in) |
| Dimensions,
mass |
57 mm (2.24 in) W × 180 mm (7.09
in) H × 16 mm (0.63 in) D, 170 g (6.0 oz) |
| Supplied
accessories |
CARRYING CASE 9398 ×1, TEST LEAD
9208 ×1 |
|
|